Measurement of radon and thoron concentrations of soil- gas in Al-Kufa city using RAD-7 detector

Main Article Content

Ali A. Al-Hamidawi

Abstract

This work represents the set of measurements of radon and thoron concentrations levels of soil-gas in Al-Kufa city in Iraq using electric Radon meter (RAD-7). Radon and thoron concentration were measured in soil-gas in 20 location for three depth of (50, 100 and 150) cm.
The results show that the emanation rate of radon and thoron gas varied from location to anther, depending on the geological formation. The Radon concentration in soil has been found to vary from (12775±400) Bq/m3 at 150 cm depth in location (sample K2) to (41.45±17) Bq/m3, for depth 150 cm in location (sample K20). The thoron concentration in soil has been found to vary from (198±8.5) Bq/m3 at 150 cm depth in location samples (K1 & K2) to undetected in the most location. These concentrations values are well below the allowed levels which it is range (0.4-40) KBq/m3.

Article Details

How to Cite
1.
Al-Hamidawi AA. Measurement of radon and thoron concentrations of soil- gas in Al-Kufa city using RAD-7 detector. IJP [Internet]. 2021 Oct. 14 [cited 2024 Dec. 22];10(19):110-6. Available from: https://ijp.uobaghdad.edu.iq/index.php/physics/article/view/736